Silicone Rubber Insulated Elements
Silicone Rubber Insulated Elements
Index > Products > Silicone Rubber Insulated Elements > Parallel Heating Cable
︳ Purpose
Keep warm onto the fluid of inside tube ,tank by heating to prevent freezing.
Electric heating bed for the greenhouse seedling cultivation.
︳ Features
Every 0.5 meters to 0.7 meters, weld heating wire and power lines individually form a continuous parallel heating cable.
Every intervals of heating load were independent , even though a section of load broke it will not cause the entire thermal zone to fail.
The maximum load 1000W under a thermocontroller ,cutting the length of PHL as required from 1 meter to 100 meters.
Standard load 40W / m , 30W / m ,20W / m ,10W / m of four versions.
︳ Application (1)
Name:Measured the temperature of PHC which be wrapped outside around the pipe.
Function:Chose the different load of PHC for keeping warm onto the fluid of inside pipe.
Test conditions:
Iron pipe with outside diameter 22 × inside diameter 19 (mm).
Iron pipe surface wrapped up aluminum foil tape.
Iron pipe sealed at both ends.
The measured temperature (reference value):
︳ Application (2)
Name:The PHC for heating water.
Function:liquid heating.
Test conditions:
2 liter vessel.
PHC with 40W /Meter × 2.5 Meter = 100W.
Room temperature 30 ℃.
The measured temperature (reference value):
Increased 18 ℃ after 30 minutes heating.
Increased 29 ℃ after 60 minutes heating.
Increased 35 ℃ after 90 minutes heating.
︳ Application (3)
Electric heating bed for greenhouse seedling cultivation.